MUP G2 SS 0.2uM NYL

Item No. 50174435
Mini-UniPrep G2 Slit Septum Cap with Translucent Housing 0.2 μm Nylon Mini-UniPrep G2 Syringeless Filters are all-in-one filters that replace syringe filters, and speed up and simplify UHPLC/HPLC sample preparation. Mini-UniPrep G2 consists of an integral borosilicate glass autosampler vial, plunger
PK1000
Price
$2,888.60
price per PK1000
excl. tax
This product cannot be ordered at the moment.
Description
Mini-UniPrep G2 Slit Septum Cap with Translucent Housing 0.2 μm Nylon
Mini-UniPrep G2 Syringeless Filters are all-in-one filters that replace syringe filters, and speed up and simplify UHPLC/HPLC sample preparation.
Mini-UniPrep G2 consists of an integral borosilicate glass autosampler vial, plunger with attached filter membrane, and septum/cap.
Glass construction of Mini-UniPrep G2 minimizes the risk of leachables contaminating the sample.
Designed to be loaded directly into the autosampler.
Visual indication that the sample has been filtered. Minimize instrument downtime due to unfiltered samples.
Wide range of membranes with 0.2 and 0.45 µm pore sizes to meet specific sample filtration requirements.
Mini-UniPrep G2 Syringeless Filters provide a fast and easy way to remove particulates from samples being prepared for Ultra High Performance Liquid Chromatography (UHPLC)/High Performance Liquid Chromatography (HPLC) analysis. In fact, Mini-UniPrep G2 lets you prepare samples three times faster compared to the syringe filter method. Due to the design of this next generation product, the filtered sample is stored within an integral borosilicate glass vial, minimizing the risk of leachables contaminating the sample.

Standardizing UHPLC/HPLC sample preparation with Mini-UniPrep G2 ensures that every sample is filtered prior to analysis, and hence minimizes instrument downtime due to unfiltered samples. The time and money saved from cutting multiple consumables out of the sample preparation process provides immediate benefits for your laboratory.

Available in a range of membranes, slit septum and amber versions (for light-sensitive samples).
Simple Operation
The Mini-UniPrep G2 glass chamber can hold up to 0.5 mL of unfiltered sample. The integral borosilicate glass vial within the plunger can hold up to 0.33 mL of filtered sample. The plunger contains a filtration membrane at one end and a pre-attached cap/septum at the other. The plunger is pressed through the sample in the outer chamber and positive pressure forces the filtrate into the glass vial contained within the plunger. Air escapes through the vent hole until the locking ring is engaged, providing an air-tight seal.

Once compressed, Mini-Uniprep G2 can be placed into any autosampler that accepts 12 mm x 32 mm vials for injection into your instrument. Alternatively, the septum can be pierced with a needle and the sample drawn off for manual injection into an analyzer.
Hand and Multi Compressor
Mini-UniPrep G2 can be used with either the hand compressor (single position) or with a multi compressor (available from Oct. 2012). The multi compressor can process up to 8 samples at one time, further improving sample processing time.
A Variety of Filters to Meet your Needs.
A range of Mini-UniPrep G2 filters is available to meet specific needs. In addition, for customers who need to filter light sensitive samples, there is Amber Mini-UniPrep. For customers using robotics to maximize throughput, we offer Slit Septa Mini-UniPrep G2.
Videos



Features:
•Mini-UniPrep G2 consists of an integral borosilicate glass autosampler vial, plunger with attached filter membrane, and septum/cap.
•Glass construction of Mini-UniPrep G2 minimizes the risk of leachables contaminating the sample.
•Designed to be loaded directly into the autosampler.
•Visual indication that the sample has been filtered. Minimize instrument downtime due to unfiltered samples.
•Wide range of membranes with 0.2 and 0.45 µm pore sizes to meet specific sample filtration requirements.

Mini-UniPrep G2 Syringeless Filters provide a fast and easy way to remove particulates from samples being prepared for Ultra High Performance Liquid Chromatography (UHPLC)/High Performance Liquid Chromatography (HPLC) analysis. In fact, Mini-UniPrep G2 lets you prepare samples three times faster compared to the syringe filter method. Due to the design of this next generation product, the filtered sample is stored within an integral borosilicate glass vial, minimizing the risk of leachables contaminating the sample.

Standardizing UHPLC/HPLC sample preparation with Mini-UniPrep G2 ensures that every sample is filtered prior to analysis, and hence minimizes instrument downtime due to unfiltered samples. The time and money saved from cutting multiple consumables out of the sample preparation process provides immediate benefits for your laboratory.

Available in a range of membranes, slit septum and amber versions (for light-sensitive samples).

The Mini-UniPrep G2 glass chamber can hold up to 0.5 mL of unfiltered sample. The integral borosilicate glass vial within the plunger can hold up to 0.33 mL of filtered sample. The plunger contains a filtration membrane at one end and a pre-attached cap/septum at the other. The plunger is pressed through the sample in the outer chamber and positive pressure forces the filtrate into the glass vial contained within the plunger. Air escapes through the vent hole until the locking ring is engaged, providing an air-tight seal.

Once compressed, Mini-Uniprep G2 can be placed into any autosampler that accepts 12 mm x 32 mm vials for injection into your instrument. Alternatively, the septum can be pierced with a needle and the sample drawn off for manual injection into an analyzer.

Simple Operation

Mini-UniPrep G2 can be used with either the hand compressor (single position) or with a multi compressor (available from Oct. 2012). The multi compressor can process up to 8 samples at one time, further improving sample processing time.

Hand and Multi Compressor

A range of Mini-UniPrep G2 filters is available to meet specific needs. In addition, for customers who need to filter light sensitive samples, there is Amber Mini-UniPrep. For customers using robotics to maximize throughput, we offer Slit Septa Mini-UniPrep G2.

A Variety of Filters to Meet your Needs.



Videos

CapSlit septum
Capacity Max.Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
ColorClear
Complete Packsize1000 Pieces
DimensionsEquivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials
(Needle height of the autosampler may need adjusting)
Filtration MediaNylon
HousingBorosilicate glass and Polypropylene (PP)
MaterialChamber: Borosilicate Glass
Plunger Outer Housing: Polypropylene
Plunger Inner Storage Vial: Borosilicate Glass
Filter media: As Specified
Septa: Silicone with PTFE Liner
Cap: Polypropylene
Nominal Force Needed to CompressApproximately 25 lbs (11.3 Kg)
Pore Size0.2
Item Info:
Item Title MUP G2 SS 0.2uM NYL
Category: Supplies
Sales Unit of Measure PK1000
Last Date/Time Modified 4/26/2023 10:20:57 AM
    Loading